The innovative, flexible and compliant flow-through detector

LabLogic’s PET/SPECT radio-HPLC Detector, the innovative Flow-RAM 2™, is designed to meet the ever increasing demands of the modern Radiopharmacy.

Flexibility

The Flow-RAM 2™ is available in a single or dual detector configuration. In the latter configuration, each of the detectors can be set up independently of each other and used for different applications, if required.

With a wide range of detectors suitable for both low and high levels of radioactivity, the Flow-RAM 2™ is an ideal quality control and research instrument.

Compliance

As with all LabLogic products, the Flow-RAM 2™ has been designed to meet regulatory requirements. The instrument contains only a power button and display so all detector parameters are controlled via the software method.

Used with our industry standard Laura™ software, the Flow-RAM 2™ ensures regulatory compliance via controlled access and audit-trail.

New Smart Detectors

Smart detectors offer a new detection technology providing improved performance and usability compared to traditional PMT detectors.

Cableless detectors

The NEW cableless detectors are automatically detected and retrieve their operating parameters from Laura™ software, ensuring GLP compliance.

Temperature controlled

Detectors are equipped with Peltier temperature control for enhanced stability and consistent performance.

A range of detectors

Suitable for PET, SPECT and gamma emitting radionuclides across a range of radioactivity levels.

Built-in Analogue Output

Users can take an analogue signal into any third party software.

Optimal Analogue to Digital Converter

This feature coverts analogue signals from other detectors such as UV, ECD, etc., into digital for use within Laura™, bringing all signals into one place.

Bespoke Lead Shielding

In order to minimise background interference LabLogic provides a range of lead shielding to meet different requirements.

LED System Status

Quick ID of operational mode or error state.

Small Footprint

Measuring just 7 (D) x 16 (L) x 15 (W) cm, the Flow-RAM is an ideal instrument when lab bench space is at a premium.

Connectivity

The Flow-RAM 2™ is compatible with all commercially available HPLC systems.

New Smart Detectors

Smart detectors offer a new detection technology providing improved performance and usability compared to traditional PMT detectors.

Cableless detectors

The NEW cableless detectors are automatically detected and retrieve their operating parameters from Laura™ software, ensuring GLP compliance.

Temperature controlled

Detectors are equipped with Peltier temperature control for enhanced stability and consistent performance.

A range of detectors

Suitable for PET, SPECT and gamma emitting radionuclides across a range of radioactivity levels.

Controlled by compliant software

Scan-RAM 2™ control, data collection, analysis and reporting is provided by Laura Radiopharmacy, the industry-standard radiochromatography data system.

Compliant

Laura Radiopharmacy can be installed and configured to meet the most rigorous regulatory compliance requirements. Featuring a configurable audit trail, multi level security, e-signatures and data storage into a secure database environment.

Single point of control

Rather than having several software systems, Laura Radiopharmacy provides a single point of control, supporting over 1,000 instruments including radio-HPLC detectors, radio-TLC scanners, gamma spectrometers, GC and HPLC modules from leading manufacturers.

Scalable

From a standalone installation to a full client server implementation, Laura Radiopharmacy offers a scalable solution to your data storage requirements. Application and data can be separated across local clients and central servers to match IT requirements.

Easy to use

Wizards guide users through configuring the software in a simple step-by-step approach. For consistency of data capture and presentation users can lock the configuration of methods, reports, etc. The new quick start wizard below makes completing a measurement as simple as two clicks.

Signal to Noise calculation

Whether you work to USP or EP, Laura Radiopharmacy has the option to calculate signal to noise in line with both requirements.

Automatic pass-fail criteria

Eliminate subjectivity, save time, and trust in your results.

Digital signal

Full dynamic range of the detector is processed avoiding limitations commonly seen with analogue signals.

Reporting

Fully configurable to meet needs of Radiochemists.

Nuclide ID

Laura Radiopharmacy can identify radionuclides by analysing samples at specific time points and using the built in half-life calculation.

Automatic peak finder

Speed up analysis with our peak finder, improving accuracy, efficiency, and consistent results across different samples.

Documents

The LabLogic Group will always treat your details with the utmost care and will never sell them to third party companies.

Please choose one of the following:



Previous
Next