Automatic radiopharmaceutical dispensing and infusion for PET

The KARL100 is an advanced mobile unit designed to automate the dispensing and infusion of FDG and other PET radiopharmaceuticals, helping nuclear medicine and PET imaging departments improve safety and efficiency. By reducing manual handling and streamlining dosing procedures, the KARL100 allows radiopharmaceuticals to be administered with greater confidence while minimising radiation exposure to staff and patients.

The KARL100 is fully compliant with MDR 2017/745 Article 22 and provides a safe, scalable, and futureproofed solution for PET imaging.

Remote, fully automated infusions

The system supports remote infusions through the Rad-Inject automated injector. It can dispense multiple patient doses and administer injections simultaneously using two or more Rad-Inject units. Weighing just 1.1 kg, the Rad-Inject eliminates the need to push heavy, bulky autoinjector carts between patients or uptake rooms. Fully automated administration also ensures staff can maintain a safe distance during injection to minimise radiation exposure.

Radiopharmaceutical Compatibility

The KARL100 is fully compatible with multiple radionuclides including:

  • Fluorine-18
  • Carbon-11
  • Lutetium-177
  • Yttrium-90
  • Radium-223
  • Gallium-68
  • Copper-64
  • Technetium-99m
  • Nitrogen-13
  • Zirconium-89
  • Iodine-123
  • Iodine-131
  • Actinium-225

Steps

Step 01 Installing

The KARL100 uses disposable injection kits. Each kit comes in a sterile packaging, each component fits into a specific slot, making installation easy and quick, taking no longer than two minutes.

Step 02 Testing

The system automatically tests the newly installed consumable kit by checking the pumps, bubble point, pressure sensors and peristaltic pump. This is intended to avoid wasting both saline solution and radiopharmaceuticals, ensuring the highest safety possible for the operator at the same time.

Step 03 Loading

Once the mother vial information has been input (total activity, calibration time and total volume), the closed transport lead pot can be positioned in its housing.

The system then automatically uncaps the lead pot, pierces the vial and draws up the whole volume. An acoustic alarm will sound once the process is complete.

Step 04 Preparing

Preparation of the patient dose begins with entering patient information into the system. This can be done manually or by downloading the patients’ list via DICOM.

Once dispensing has started, the whole dispensing procedure is automatic and ends with the patient dose transferred into the Rad-Inject. A label with patient information is also printed at this point.

Step 05 Injecting

The Rad-Inject is then transferred onto the stand and connected to the patient and the infusion process starts.

During the infusion, the operator can begin preparing the next patient dose on the same KARL100. This novel feature for dispensing and infusing PET radiopharmaceuticals provides greater flexibility, allowing departments to maintain a steady patient throughput and minimise exposure.

Features

Mother Vial

In the KARL100, the mother vial is housed in a shielded compartment that ensures radiation protection and is managed through a fully automated, safe and sterile process. The system precisely dispenses the required amount of radiopharmaceutical for each dose, preventing waste and ensuring that the patient is never directly connected to the mother vial, eliminating the risk of cross-contamination.

Dose Calibrator

The dose calibrator is installed inside the centre of the KARL100. It is a third-party Class IIb medical device in accordance with Annex II of Directive 93/42/EEC (excluding point 4) and features a measurement chamber designed to measure radioactivity.

Filling Area

The filling area is equipped with a ventilation system that uses an H14 HEPA filter to ensure Grade A air quality in critical areas. The KARl100 is the only dose dispenser available capable of filling syringes in a GMP Class A (ISO 5) environment.

Lead Pot

The lead pot can safely house shielded containers of different sizes and models from all manufacturers. The pot’s loading area automatically opens to eliminate manual intervention precisely when radioactivity is at its highest. This limits the risk of exposure and ensures safer handling of the radiopharmaceutical.

Touchscreen

The built-in touchscreen’s user interface allows users to control, monitor and configure the KARL100.

Label Printer

The DYMO LabelWriter 450 Turbo is the standard printer for the KARl100 and is installed underneath the touchscreen. The system’s software allows labels to be configured and printed with barcodes.

Sterility

An in-line 0.22 µm filter screens the incoming activity from the mother vial. A dedicated vented area for the syringe connection with a Class A Laminar Flow prevents microbial contamination.

Dosimetry Monitoring

A Geiger-Müller counter housed in the KARL100 provides continuous real-time dosimetry monitoring.

Outer Cover

The top cover, made of high-density polyurethane, protects the operator from accidental contact during operation.

Specifications

Rad-Inject Automated Injector

Weight 1.1. kg
Length 163 mm
Classification Class 2b (CE 0476) Medical Device
Power Supply Lithium Battery

Rad-Inject Automated Injector

Weight 445 kg
Dimensions W 540 x D 1160 x H 1070 cm
Power Supply 110/220 VAC 50/60 Hz + Built-in Lithium Battery
Power Requirement Max 300 Watts
Classification Class 1m (CE 0476) Medical Device

KARL100 existing users

Click the tabs below to find out more about how existing sites are using the KARL100.

Alliance Medical, Guildford, UK

Alliance Medical Limited has recently chosen the Karl100 Multi-Dose Administration System for their radiotracer dispensing at their new Guildford PET-CT Centre. The system, set to be installed later this year, will go into the state-of-the-art facility based at Surrey Research Park.

In partnership with the Royal Surrey NHS Foundation Trust, the centre will help reach more patients by increasing scanning capacity and reducing waiting times. The Karl100 will be used primarily for FDG PET-CT scans and will greatly help with both operator and patient safety.

LEARN MORE

Charing Cross Hospital, London, UK

Charing Cross Hospital has recently had a Tema Sinergie Karl100 multi-dose administration system installed in their Imaging Department. The unit will be used to inject patients with radiotracers prior to PET scans.

We spoke with Luis Alves, PET Modality Lead in the Imaging Department, to find out how the Karl100 has improved departmental safety and patient care.

LEARN MORE

Documents

The LabLogic Group will always treat your details with the utmost care and will never sell them to third party companies.

Please choose one of the following:



Previous