Designed for Radionuclidic Identity
The ideal solution for spectroscopic analysis of samples with low radionuclidic activity (ascertaining radionuclidic impurities in the sample).
The Spec-RAM™ is a high-performance fully integrated detector and multi-channel analyser solution that contains everything needed to support scintillation spectrometry.
With its simple and intuitive operation, Spec-RAM™ is the perfect solution for radiopharmacies.
User friendly
LabLogic developed the Spec-RAM™ specifically for PET/SPECT application, with a range of features aimed at ensuring the system is user friendly, compliant, safe and reliable.
Flexibility
The Spec-RAM™ is available in four different detector models. The different detectors are interchangeable providing for future proofing should requirements change. Detector models are:
2" x 2" (51 x 51 mm) NaI(Tl) end-on |
2" x 2" (51 x 51 mm) NaI(Tl) well-geometry (well dimensions: 16.6 mm dia. x 39 mm) |
3" x 3" (76 x 76 mm) NaI(Tl) end-on |
3" x 3" (76 x 76 mm) NaI(Tl) well-geometry (well dimensions: 16.6 mm dia. x 51 mm) |
Compliance
As with all LabLogic products, the Spec-RAM™ has been designed to exceed regulatory requirements. Using our industry standard Laura Radiopharmacy software, the Spec-RAM™ ensures regulatory compliance via controlled access and audit trail.
Audit Trail
Laura Radiopharmacy has a fully featured audit trail that can again be configured to suit the requirements of the user site. Response from the user can be a simple as choosing from a pre-defined list of standard audit reasons or require a unique response depending on the situation and site rules.
Access Levels
Laura Radiopharmacy features multi-level access control and the system can be configured to have as many levels of access as the user site requires. Menu items are then restricted according to the security level of the individual logged in.
Electronic Signatures
Laura Radiopharmacy supports the use of electronic signatures and the system can be configured to suit the user sites requirements for electronic data.
Data Integrity
Regulatory compliance is an essential feature of Laura Radiopharmacy, built to meet GLP/GMP, MHRA and FDA 21 CFR part 212 / 11 requirements. Featuring configurable audit trail, electronic signatures, secure data storage in a database environment and multi-level security Laura Radiopharmacy can be configured to meet regulatory requirements for data integrity.
Security Settings
Laura Radiopharmacy can be configured to suit your particular site requirements for security. User names and passwords can be controlled relative to the site requirements as can inactivity time outs and all other functions required for a secure system.
Common Specifications | |
HV Supply | Positive bias from MCA; 600 - 800 Vdc |
Operating Temperature | -20 to +65°C |
Typical Energy Resolution | 7.5 +/- 0.2 % FWHM @662 keV |
Energy Range | 20 keV - 3 MeV |
Gain Stability | <1.0% over 24 hours at 20°C |
MCA | 1024/2048 Channel, selectable |
Lead Shielding Specifications | |
Weight | 138 kg |
Lead Thickness | 50 mm |
Dimensions | 521 x ∅ 216 mm |
Spec-RAM existing customers
Click on the tabs below to find out more about our customers, and how they are using the Spec-RAM in their facilities.
Documents
-
Spec-RAM-EU-Version-1.3
Download (1.94 MB) -
Spec-RAM-Detectors-Datasheet-EU-Version-1.1
Download (51.25 kB) -
Solutions-for-Radiopharmacy-EU-Version-1.1
Download (15.57 MB)